Easily put the Smart into your Home
UPB Switches:
The most reliable, customizable, and easy-to-install Power Line Automation switches ever made. ZERO New Wires Required!
|
Only $79.95
|
View All Switches »
|
|
|
 |
Shop > ELK Products > ELK-RP
|
ELK M1 Remote Programming Software, FREE with 1st Control Purchase
|
|
|
|
Enlarge Image
|
For use with the ELK-M1 Security, Automation & Phone Control System. The ELK-RP Remote Programming Software is FREE with 1st Control Purchase.
ElkRP is a state-of-the-art environment for maintaining the setup of customers’ accounts. It is much more than just an upload/download software package. It is a database-driven application with an intuitive user interface that allows you to see, at a glance, all the information pertinent to a specific installation.
|
|
|
|
|
|
All the accounts in the database are listed in a tree-like view, allowing you to quickly select one. You can edit an account off-line, then connect to the system and download the entire account, or connect first and then edit the account item-by-item. Best of all, writing rules for the Elk M1 is a snap with ElkRP’s Rules Programming Engine.
Key features include:
- A user interface consistent with most Microsoft Windows applications.
- Scalable from a one-man operation to a large corporation.
- Sorting of accounts in a hierarchical tree arrangement.
- Supports account templates for creating new accounts.
- Detects differences between the system and the database with easy resolution of those differences.
- Sending and receiving individual pieces or groups of data as well as the entire program.
- Automatic un-attended operation (answer and download).
- Multiple users with unique levels of access.
- Connects directly through your computer’s serial port, through a modem, or a network.
- Works with any brand modem, not just Hayes.
- Automatically bypasses answering machines.
- Downloads software updates to controls, keypads, etc.
- Prints a variety of reports.
- Viewing of a system’s current status with remote arming, disarming, zone bypassing, etc.
And much, much more.
|
ElkRP Demo (12.5MB)
Full featured ElkRP software except cannot connect to a control.
Computer Requirements:
Windows 98, Windows 98 SE, Windows NT 4.0, Windows 2000, Windows XP, Windows Me.
Pentium-Pro 600 MHz or faster.
256 MB minimum System Memory.
12 MB minimum free Hard Disk space.
The ELK M1 Integrates – Security – Automation – Lighting – Telephone. Available in two Versions: ELK-M1 (Standard) and ELK-M1G (Gold) (see comparison chart)
The M1 Controller family offers unequaled value to Systems Integrators, Installers and End Users alike. Unlike panels that may be strong in automation but weak in security (or vice versa), the M1 boasts a rock solid security foundation with the most imaginative and powerful automation functionality available.
Integrators and Installers will value the flash memory firmware, RS-232 serial port, ethernet connectivity option, fast PC programming and ease of installation resulting in reduced work time. M1 offers the flexibility to integrate industry standard systems and components for easy upgrades and system expansion.
End users will welcome the quality and futuristic capabilities of the versatile keypad and the built-in telephone remote. The 500+ word vocabulary pleasantly announces system status, configurable in any sequence to alleviate user intimidation.
Choose from the full feature ELK-M1G (Gold) or the powerful ELK-M1 standard. Both are designed to exceed your expectations while expanding your earnings potential.
M1...Experience the Industry's Most Advanced Cross Platform Control.
Features & Benefits Common to Both ELK-M1 (Standard) and ELK-M1G (Gold)
|
- Large zone capacity: 16 on-board zones expandable to 208
- Wireless capability: Up to 48 zones
- Two-way Listen-in interface
- Flash Memory - Allows field updates to firmware electronically
- RS-232 Serial Port to interface to computers and peripheral devices
- Time/Date stamped 512 event history log
- Menu driven, full text keypad programming - no manual required!
- Voice Announcement of alarms, zone descriptions, status, etc.
- 500+ Word/phrase Vocabulary
- Link up to 6 words/phrases per announcement
- 10 custom recordable word/phrases
- 13 On-board Outputs: 1 voice/siren, 1 siren driver, 1 form "C" relay and 10 low current (50mA) outputs
- Supports 4-wire (any zone) and 2-wire (zone 16) smoke detectors
- Includes fire alarm verification routine
- Can be partitioned into 8 separate areas and account numbers
- User Codes: 99 (4 or 6 digit) with assignable authority levels
- Arm levels: Away, Stay, Stay Instant, Nite, Nite Instant, Vacation
- Plug-in terminal blocks make service and pre-wires a snap!
- Hardware "watchdog" and nonvolatile EEPROM memory
- Supervised phone line, alarm output and aux. overcurrent
Communications
|
- True V.22 bis Modem for fast, reliable upload/download
- Optional Ethernet port for reporting operation / control or programming
- Built-in telephone remote control makes any phone a keypad
- Integrated Voice Dialer uses vocabulary or custom word/phrases
- Digital Communicator formats: SIA, Contact ID, 4+2 and Pager
- Installer Telephone (butt set) test feature
- Elk-RP PC software includes "conflict resolution" to easily highlight differences between control and PC
- Dial-up, ethernet or local from RS-232 port or house phone jack
- Automatic answering machine bypass
Keypad
|
- Backlit, Large Character LCD Display: 16 x 2 lines
- Built-in Temperature Sensor
- Optional Plug-in Prox Access reader (26 bit Weigand format)
- Menu navigation keys and 6 programmable function keys
- Plug-in connector: Only 4 wires to the control
- 1 Zone Input and 1 Output Programmable per Keypad
- Programmable display of time, date and temperature
- Displays system diagnostics and settings
- System supports up to 16 keypads
Automation & Integration
|
- Create lifestyle enhancing comfort, convenience and security
- Powerful "Whenever/And/Then" RULES Programming allows almost any imaginable operation. No need to chain rules together. Any single "Whenever" event can can have one or more ANDs and THENs (conditions and commands).
- Rules utilize easy to understand text based references
- Control lighting using RS-232 serial or 2-way Power Line Control (PLC) ports including On, Off, Dim All On, All Off commands
- Transmit and receive custom serial ASCII messages
- Read temperature sensors and communicate with thermostats
- Turn on Tasks, Lights, Outputs via Keypad or Telephone Remote
Power Supply
|
- Heavy Duty - 2.5 Amp power supply w/ 1.5 Amp continuous
- Dynamic battery test
- Master power switch and low battery disconnect
- PTC (fuseless) resettable overload protection
- Multiple auxiliary power terminals
Part Numbers and Accessories:
|
- ELK-M1 Standard M1 Control in 14” x 14” enclosure
Standard System Packages:
ELK-M1SYS1 Control, Enclosure, & Transformer
ELK-M1SYS2 Control, Enclosure, Xfmr, & Keypad
ELK-M1SYS3 Ctrl, Encl,Xfmr, KP, & 12V-8Ah battery
ELK-M1SYS4 Ctrl, Encl, Xfmr, KP, 12V-8Ah, Spkr, RJset
- ELK-M1G M1 GOLD Control in 14” x 14” enclosure
Gold System Packages:
ELK-M1GSYS1 Control, Enclosure, & Transformer
ELK-M1GSYS2 Control, Enclosure, Xfmr, & Keypad
ELK-M1GSYS3 Ctrl, Encl,Xfmr, KP, & 12V-8Ah battery
ELK-M1GSYS4 Ctrl, Encl, Xfmr, KP, 12V-8Ah, Spkr, RJset
- ELK-M1KP Keypad, LCD,16 character x 2 line
- ELK-M1XIN 16 Zone (input) expander
- ELK-M1XOVR 16 Output expander, 8 Voltage/8 Relays
- ELK-M1XOV 16 Output expander, Voltage only
- ELK-M1RB Relay board, 8 form ”C” relays
- ELK-M1DBH Data bus wiring hub
- ELK-M1XEP Ethernet Port Expander/Interface
- ELK-M1XSP Serial port expander
- ELK-M1PR Mini prox reader for keypad
- ELK-M1PRC Proximity Card for ELK-M1PR Reader
- ELK-M1PRF Proximity Fob for ELK-M1PR Reader
- ELK-M1VB Voice Board replacement (included on standard M1 boards)
- ELK-SWP3 Multipurpose Adapter Plate, 3 inch with plastic standoffs
- ELK-USB232 Serial cable to convert USB to RS232
- ELK-M1TWI Two Way Listen-in Int. w/3 mic inputs
- ELK-M1TWS Speaker & Mic for Two Way Listen-in
- ELK-M1TS Temperature Sensor -40 to 150 degrees F
- ELK-RP PC software, FREE with 1st Control purchase
|
Comparisons of ELK-M1(Standard) and ELK-M1G(Gold) |
ELK-M1 (Std) |
ELK-M1G (Gold) |
|
Automation rules capacity |
20 |
528 |
|
Keypads supported |
4 |
16 |
|
Serial (RS232) port supported |
1 |
8 with expanders |
|
Phone number capacity |
4 |
8 |
|
Number of HVAC thermostats supported |
1 |
8 |
|
Total number of outputs supported |
20 |
205 |
|
Advanced lighting options (pre-set dim, extended, levels, scenes) |
- |
Yes |
|
Analog zone definitions supported |
- |
Yes |
|
Additional capacity for transmission of serial ASCII strings |
- |
Yes |
|
Sunrise/sunset calculation and activation |
- |
Yes | |
Larger capability for events (time & date) tasks, lights, outputs |
- |
Yes |
|
|
|
|
|
|
|
|
 |
 |
|