ACT Multi-Tester Transceiver - AT004
Generate test signals to verify proper receiver operation. X10 and A10 Programming Tool. Display signal strength on line from other transmitters and two way receivers. Pinpoint loads to be filtered by logging power grid noise levels. Rated 120 to 277 VAC.
View Product Details
$251.95
ACT Passive Phase Coupler - CP000
Isolating phase coupler used to transfer command signals generated on one phase of single-phase or a three-phase system to one or two of the remaining phases. X10 & A10. Rated 120, 277 VAC, 4 Wire, 1:1 Ratio.
View Product Details
ACT Single Pole 20A 277V AC Feed Thru Relay Receiver without "All Lights ON" - RB310
This feed through fixture module provides users with unmatched versatility and convenient installation. The module can be installed at a panel, junction box, or in the fixture itself. This type of installation is fast, inexpensive, and also allows for great flexibility in load control planning as the switching modules can be placed anywhere in the circuit to control the entire circuit, or only selected loads with both A10 or X10.
View Product Details
$12.95
ACT Wall Mounted Dimmer Switch - RD104
Dimmer Switch can store DIM levels for easy re-creation of lighting levels (scenes). Switch provides remote ON/OFF and Dimming control of lighting. X10/A10. Rated 600W, 120 VAC.
View Product Details
X10 / A10 120VAC, 500W, SP, 3-Way or Single Inductive Dimmer - RD161
Looking for an easy way to automate low-voltage lighting and motor loads such as ceiling fans? You've found it. This inductive dimmer switch gives you the power to control low-voltage lights, ceiling fans and other inductive devices locally at the switch or remotely from any X10 transmitter.
View Product Details
ACT Isolated Contact Relay Fixture Receiver - RF114
X10/A10 Isolated Contact Relay Fixture Receiver (20A, 120 VAC). 20 Amp isolated contact form A latching relay. Relay holds last commanded state on power loss, and A10 circuitry remembers last relay state for correct status report upon power loss.
View Product Details
ACT Relay Fixture Receiver - RF204
X10/A10 Feed-thru Relay Fixture Receiver, Standard and Extended Addressing (20A, 240 VAC). Form C Relay capable of switching a 30 amp load. Close or open relay via Standard or Extended X10 commands.
View Product Details
Item is Discontinued
ACT Isolated Contact Relay Fixture Receiver - RF214
20 Amp isolated contact form A latching relay. Relay holds last commanded state on power loss, and A10 circuitry remembers last relay state for correct status report upon power loss. X10/A10. Rated 20A, 208/240 VAC.
View Product Details
Item is Discontinued
ACT Feed-thru Relay Fixture Receiver - RF224
20 Amp isolated contact form A latching relay. Relay holds last commanded state on power loss, and A10 circuitry remembers last relay state for correct status report upon power loss. X10/A10. Rated 20A, 208 VAC.
View Product Details
ACT Feed-thru Fixture Relay Receiver, 277V AC, 15A - RF310
This feed through fixture module provides users with unmatched versatility and convenient installation. The module can be installed at a panel, junction box, or in the fixture itself. This type of installation is fast, inexpensive, and also allows for great flexibility in load control planning as the switching modules can be placed anywhere in the circuit to control the entire circuit, or only selected loads with both A10 or X10.
View Product Details
$10.95
ACT Isolated Contact Relay Fixture Receiver - RF314
20 Amp isolated contact form A latching relay. Relay holds last commanded state on power loss, and A10 circuitry remembers last relay state for correct status report upon power loss. X10/A10. Rated 20A, 277 VAC.
View Product Details
ACT Isolated Contact Relay A10/X10 Receiver, 208/240 VAC, 20A - RI223
This Isolated Contact Relay X10 and A10 receiver, benefits users with convenient installation and single pole switching for any application. These modules switch loads at line voltages which may differ from the control voltage, and install at panels, junction boxes, or right at the load site. Now with new A10 enhanced circuitry, which increases the ability to detect signal by three times that of competive products.
View Product Details
ACT Feed Thru Wall Switch Receiver - RS104
Switch can be controlled from remote location by another similar addressed transmitter. Switch provides remote ON/OFF control of lighting or any electrical load. X10/A10, Standard and Extended Addressing. S.P.; 20A, 120 VAC.
View Product Details
Item is Discontinued
ACT True-Rocker Switch, Commercial Relay Receiver - RS114
Switch can be controlled from remote location by another similar addressed transmitter. Switch provides remote ON/OFF control of lighting or any electrical load. S.P., 120 VAC, 20 Amp, Feed Thru. X10/A10, Standard and Extended Addressing.
View Product Details
$33.95
ACT True-Rocker Switch, Residential Relay Receiver - RS115
Switch can be controlled from remote location by another similar addressed transmitter. Switch provides remote ON/OFF control of lighting or any electrical load. S.P., 120 VAC, 15 Amp, Feed Thru, X10/A10, Standard and Extended Addressing. Available in White and Ivory.
View Product Details
ACT Feed Thru Wall Switch Receiver - RS304
Switch can be controlled from remote location by another similar addressed transmitter. Switch provides remote ON/OFF control of lighting or any electrical load. X10/A10, Standard and Extended Addressing. Rated 277 VAC.
View Product Details
ACT Wall/Box Mounted Transmitter Base, 120 VAC - TB100
This wall mounted transmitter sends PCC command signals to PCC X10 and A10 Receiver Modules, which switch their designated loads. Signals are transmitted to Receiver Modules over existing AC power lines, so dedicated wiring for the system components is not necessary.
View Product Details
ACT Wall/Box Mounted Transmitter Base, 227 VAC - TB300
This wall mounted transmitter sends PCC command signals to PCC X10 and A10 Receiver Modules, which switch their designated loads. Signals are transmitted to Receiver Modules over existing AC power lines, so dedicated wiring for the system components is not necessary. 227V version
View Product Details
ACT X10 / A10 64 Channel Load Controller, 120VAC - TD140
The TD140 is a compact, manually operated, 64 channel X10 / A10 transmitter in a keyboard design, allowing ON/OFF
control of room heating and air conditioning units and other electrical loads, and is expandable to control up to 256
separate electrical loads.
View Product Details
ACT 4 Button Keypad, 3 On/Off Sequenced, 1 All On/Off - TK040
The TK040 and TK041 4-button keypads send ON and OFF commands to three sequential addresses and ALL LIGHTS ON and ALL UNITS OFF commands to all appropriate Receiver Modules in the system set to the same Letter Code. For use with a TB100 or TB300 base.
View Product Details
Item is Discontinued
ACT 4 Button Keypad, 3 On/Off Sequenced, 1 Dim Control - TK050
The TK050 and TK051 4-button keypads send ON and OFF as well as DIM and BRIGHT commands to incandescent lighting controlled by appropriate PCC Receiver Modules capable of full-range dimming. By pressing the three topmost control rockers simultaneously, or in rapid sequence, all three addresses can be dimmed simultaneously by the 4th DIM/BRIGHT button. For use with a TB100 or TB300 base.
View Product Details