  ACT Multi-Tester Transceiver
 
ACT Multi-Tester Transceiver
Enlarge Image
Application:
  • Generate test signals to verify proper receiver operation.
  • X10 and A10 Programming Tool
  • Display signal strength on line from other transmitters and two way receivers
  • Use to test potential installation sites for possible installation problems
  • Pinpoint loads to be filtered by logging power grid noise levels (user defined time periods up to 24 hours).
Item # AT004
$251.95  
Shipping Rates
Free Technical Support
Low Prices Guaranteed!
Availability:
Item is Available
Display All:
ACT
Overview Related Items FAQ More Info Photos x10
Description:
The AT004 is an X10 Transceiver, able to send and receive A10 enhanced or standard X10 signals. Keypad selections enable selection of transmit signal levels, single or continuous signal transmission, user selection of zero crossing degree shift and display or log the level of noise or signal on the power line on AT004's Liquid Crystal Display (LCD).

Features:
  • Transmits X10 and Receives A10 and standard X10 (including Preset Dim) and extended code
  • Displays noise level on the power line
  • Displays signal level on the power line
  • Can log noise and signal levels over 24 hour period
  • Auto transmit mode for system testing
  • Adjustable transmit voltage in 33.3mv increments
  • Time/Date (24 Hour Format)
  • Selectable 0°, 30°, 60°, 90°, 120°, 150° transmit pulse
  • Shows received X10 packets as one frame or two frames...can be used to determine whether signal is repeated or original
  • Can be used as P1 Test Transmitter
Specifications
Electrical Parameters
Power
Supply Voltage120 to 277 VAC, +/- 10%
Frequency50 or 60 Hz.
Current Draw 315mA (rms) at 120 VAC, 60 Hz
250mA (rms) at 115 VAC, 50 Hz
280mA (rms) at 208 VAC, 60 Hz
325mA (rms) at 240 VAC, 60 Hz
270mA (rms) at 240 VAC, 50 Hz
380mA (rms) at 277 VAC, 60 Hz
Circuit Protection:The AT004 circuit is protected by a 500 milliamp, 350 V, Time Lag, nonremovable fuse for over-current protection.
Receive ParametersThe AT004 will accept power line carrier transmission signals with minimum strength of 25mV peak to peak. The carrier frequency of this signal will be 120kHz ±4kHz. The pulse width will be 1ms ±10% and occur no later than 200ms after the zero crossing of the main voltage
General Transmit ParametersThe AT004 will output power line carrier transmission signal with a minimum of 6V peak to peak strength into a power line with a 5W load attached. The carrier frequency will be 120 kHz ±1kHz. The transmission pulse will be 1ms ±10% and will start no later than 200ms after the zero crossing of the mains voltage and when enabled an additional pulse will be transmitted no later than 200ms after the 30° point of the half wave.
Transmit LocationsAll transmission locations (0°, 30°, 60°, 90°, 120°, & 150°) can be individually activated or deactivated through the SETUP menu.

NOTE: More than four activated transmit locations may deliver unsteady transmit level results.

NOTE: The 0° transmit location must remain enabled if the automatic level adjustment is to remain active. If the 0° transmission is disabled, the circuit will always adjust to maximum transmit level.
Transmit Level:The level of the powerline carrier transmissions can be adjusted through the setup menu. When the level is set from 0 to 150 the Automatic level adjustment will be active. This will readjust the signal level for line loading conditions. The maximum adjustable level is 5V peak to peak (level setting of 150). Any setting above this will result in a maximum output (>/= 6V peak to peak).
Display16 Character x 2 Row LCD, Bottom viewing angle. Contrast adjustment is possible with adjustment potentiometer on the right side of the case.
Mechanical Parameters
Dimensions4.00" W x 7.50" L x 2.13" H
Weight16 oz.
Power Connection Socket:Keyed Header
120 VAC Power Cable:Two Prong Polarized Plug on 4 ft. cord to Locking Keyed Receptacle (ACT Replacement Part No. HW080).
208 to 277 VAC Power Cable:Insulated Alligator Clip Connections on 5 ft. cord to Locking Keyed Receptacle (ACT Replacement Part No. HW076).
Membrane Keypad:The membrane switch keypad has a minimum cycle life of 1,000,000 cycles/compressions of each key.
Environmental Requirements
Operating Temperature Range32 to 120° F (0 to 49°C)
Storage Temperature Range-20 to 150° F (-29 to 66°C)
Operating Humidity Range10% to 95% non-condensing