- CR134 Repeats X10 & A10 powerline carrier transmission signal on all
phases of a 120/208 VAC three phase power system,
when it is received on one phase or on the Signal Carrying Conductor (SCC).
- CR334 Repeats X10 & A10 powerline carrier transmission signal on all
phases of a 277/480 VAC three phase power system,
when it is received on one phase or on the Signal Carrying Conductor (SCC).
|
|
|
|
|
|
|
Description:
The CR134 and CR334 are A10 enhanced powerline
carrier coupler repeaters for distributing Powerline
Control signals to all phases of power. Both have
DIP switches that enable the user to customize
their operation depending on the application.
Both are housed in a grey painted enclosure that is
designed to mount on a 4-11/16" by 4-11/16"
electrical box. LED's in the cover indicate operational
modes.
Features:
|
- Designed to mount on a 4-11/16" x 4-11/16" electrical box
- X10 Signal and SCC (Signal Carrying Conductor) Compatible
Smart SCC - Always enabled. Does not repeat SCC signals
received on the SCC line.
- Status LED's visible on Cover
- Equipped with Quick Fit spade terminals for wiring connections
- Fuse Protected - Field Replaceable
- Improved receive signal response, higher signal output
- Internal DIP switches can select special features such as:
- Priority SCC - Will allow Signal Carrying Conductor signal to take priority over any other code being received.
- Receive at 0° or 30° - Either one.
- Repeat or Ignore Repeated Signal - "Repeat repeated" enabled repeats all signals including those from other
repeaters. "Ignore Repeated" repeats all signals except those from another repeater.
- Handles Preset Dim commands
- X10 Extended Code 1 or ACT Extended Code - Can accept either, one at a time.
- Repeat on ALL Active Phases/Repeat on SCC only
- Window Normal/Window Sensitive - Shifting the sine wave to the window sensitive mode can improve
reception in selected installations.
| Specifications |
| Electrical Requirements |
| Power |
| Supply Voltage | 120 VAC, +/-10% |
| Fuses (field replaceable) | Phase A: 5x20mm, 750mA, 250V, Time Lag Fuses
Phase B & C: 5x20mm, 500mA, 250V, Time Lag Fuses |
| Signal Input | X10 Powerline Carrier on any phase, Signal Carrying Conductor (SCC), both sensitive to 25 millivolts |
| Signal Output | X10 Powerline Carrier (including SCC), 5V peak to peak @ 5 ohms |
| Mechanical Requirements |
| Mechanical Connection | Four (4) Quick Fit 0.25" spade terminals installed in tri-barrier terminal block under screw clamp connections.
Provided: Four (4) female quick disconnect wire connectors for 14 to 16 AWG wire. |
| SCC Connections | Plug-in terminal block |
| SCC Wire Size | 12 to 22 AWG |
| SCC Wire Strip Length | 5/16" |
| Dimensions (Enclosure) | 4.75" L x 4.75" W x 2.0" H |
| Weight | Less than 16 ounces |
| Mounting | Hinges/mounts on 4-11/16" x 4-11/16" electrical junction box |
| Environmental Requirements |
| Operating Temperature Range | 32 to 120° F (0 to 49°C) |
| Storage Temperature Range | -40 to 185° F (-29 to 66°C) |
| Operating Humidity Range | 10% to 95% non-condensing |
|
|
|
|
|
|
|
|
|
 |
 |
|