Smart Home Systems

smart The Smartest DIY Home Improvements

house  Home Automation, Security & Energy Savings
         
 Phone Orders: 1-888-843-9103 | 631-361-3600
                                  
 
smart
Search
 
Shop

Motorola Homesight
Motorola Homesight:
Everything you need to install a do-it-yourself home monitoring system for security, protection, and convenience.

Homesight Only $98.95!

Read More
View Video Demo ยป


  Shop > ACT > CR244
x10
  ACT Split-Single Phase Coupler Repeater
 
ACT Split-Single Phase Coupler Repeater
Enlarge Image
Applications:
CR244 Repeats X10 & A10 powerline carrier transmission signal on all phases of a 240/415 VAC 50 Hz three phase power system, when it is heard on one phase or on the Signal Carrying Conductor (SCC).
Item # CR244
$236.95  
Low Prices Guaranteed!
Free Technical Support
Shipping Rates
Availability:
Special Order
Display All:
ACT
Overview FAQ More Info Photos x10
Description:
The CR244 is an A10 enhanced powerline carrier coupler repeater for distributing Powerline Control signals to all phases of power. It has DIP switches that enable the user to customize its operation depending on the application. CR244 is housed in a grey painted enclosure that is designed to mount on a 4-11/16" by 4-11/16" electrical box. LED's in the cover indicate operation modes.

Features:
  • Designed to mount on a 4-11/16" x 4-11/16" electrical box
  • X10 Signal and SCC (Signal Carrying Conductor) Compatible Smart SCC - Always enabled. Does not repeat SCC signals received on the SCC line.
  • Status LED's visible on Cover
  • Internal Screw terminals for wiring connections
  • Fuse Protected
  • Improved receive signal response, higher signal output
  • Internal DIP switches can select special features such as:
    • Priority SCC - Will allow Signal Carrying Conductor signal to take priority over any other code being received.
    • Receive at 0O or 30O - Either one.
    • Repeat or Ignore Repeated Signal - "Repeat repeated" enabled repeats all signals including those from other repeaters. "Ignore Repeated" repeats all signals except those from another repeater.
    • X10 Extended Code/ACT Extended Code - Can accept either, one at a time.
    • Repeat on ALL Active Phases/Repeat on SCC only
    • Window Normal/Window Sensitive - Shifting the sine wave to the window sensitive mode can improve reception in selected installations.

Specifications
Electrical Requirements
Power
Supply Voltage240 VAC, +/-10%
Fuses (field replaceable)Phase A: 5x15mm, 750 mA, 350V, Time Lag
Phase B: 5x15mm, 500mA, 350V, Time Lag
Phase C: 5x15mm, 500mA, 350V, Time Lag
Signal InputX10 Powerline Carrier on any phase, Signal Carrying Conductor (SCC), both sensitive to 25 millivolts
Signal OutputX10 Powerline Carrier (including SCC), 5V peak to peak @ 5 ohms
Mechanical Requirements
Mechanical ConnectionFour (4) Quick Fit 0.25" spade terminals installed in tri-barrier terminal block under screw clamp connections.

Provided: Four (4) female quick disconnect wire connectors for 14 to 16 AWG wire.
SCC ConnectionsPlug-in terminal block
SCC Wire Size12 to 22 AWG
SCC Wire Strip Length5/16"
Dimensions (Enclosure)4.75" L x 4.75" W x 2.0" H
WeightLess than 16 ounces
MountingHinges/mounts on 4-11/16" x 4-11/16" electrical junction box
Environmental Requirements
Operating Temperature Range32 to 120° F (0 to 49°C)
Storage Temperature Range-40 to 185° F (-29 to 66°C)
Operating Humidity Range10% to 95% non-condensing
Return to Top
Contact Us |  Link To Us |  Copyright © 1997 - 2008 Smart Home Systems, Inc. All rights reserved |  Sitemap