x10
  ACT Coupler Repeater
 
ACT Coupler Repeater
Enlarge Image
Applications:
  • CR134 X10 & A10 Repeats powerline carrier transmission signal on all phases of a 120/208 VAC three phase power system, when it is received on one phase or on the Signal Carrying Conductor (SCC).
  • CR334 Repeats X10 & A10 powerline carrier transmission signal on all phases of a 277/480 VAC three phase power system, when it is received on one phase or on the Signal Carrying Conductor (SCC).
Item # CR334
$267.95  
Low Prices Guaranteed!
Free Technical Support
Shipping Rates
Availability:
Item is Available
Display All:
ACT
Overview FAQ More Info Photos x10
Description:
The CR134 and CR334 are A10 enhanced powerline carrier coupler repeaters for distributing Powerline Control signals to all phases of power. Both have DIP switches that enable the user to customize their operation depending on the application. Both are housed in a grey painted enclosure that is designed to mount on a 4-11/16" by 4-11/16" electrical box. LED's in the cover indicate operational modes.

Features:
  • Designed to mount on a 4-11/16" x 4-11/16" electrical box
  • X10 Signal and SCC (Signal Carrying Conductor) Compatible Smart SCC - Always enabled. Does not repeat SCC signals received on the SCC line.
  • Status LED's visible on Cover
  • Equipped with Quick Fit spade terminals for wiring connections
  • Fuse Protected - Field Replaceable
  • Improved receive signal response, higher signal output
  • Internal DIP switches can select special features such as:
    • Priority SCC - Will allow Signal Carrying Conductor signal to take priority over any other code being received.
    • Receive at 0° or 30° - Either one.
    • Repeat or Ignore Repeated Signal - "Repeat repeated" enabled repeats all signals including those from other repeaters. "Ignore Repeated" repeats all signals except those from another repeater.
    • Handles Preset Dim commands
    • X10 Extended Code 1 or ACT Extended Code - Can accept either, one at a time.
    • Repeat on ALL Active Phases/Repeat on SCC only
    • Window Normal/Window Sensitive - Shifting the sine wave to the window sensitive mode can improve reception in selected installations.

Specifications
Electrical Requirements
Power
Supply Voltage277 VAC, +/-10%
Fuses (field replaceable)Phase A: 5x15mm, 750mA, 350V, Time Lag Fuses
Phase B & C: 5x15mm, 500mA, 350V, Time Lag Fuses
Signal InputX10 Powerline Carrier on any phase, Signal Carrying Conductor (SCC), both sensitive to 25 millivolts
Signal OutputX10 Powerline Carrier (including SCC), 5V peak to peak @ 5 ohms
Mechanical Requirements
Mechanical ConnectionFour (4) Quick Fit 0.25" spade terminals installed in tri-barrier terminal block under screw clamp connections.

Provided: Four (4) female quick disconnect wire connectors for 14 to 16 AWG wire.
SCC ConnectionsPlug-in terminal block
SCC Wire Size12 to 22 AWG
SCC Wire Strip Length5/16"
Dimensions (Enclosure)4.75" L x 4.75" W x 2.0" H
WeightLess than 16 ounces
MountingHinges/mounts on 4-11/16" x 4-11/16" electrical junction box
Environmental Requirements
Operating Temperature Range32 to 120° F (0 to 49°C)
Storage Temperature Range-40 to 185° F (-29 to 66°C)
Operating Humidity Range10% to 95% non-condensing
Return to Top
Contact Us |  Link To Us |  Copyright © 1997 - 2008 Smart Home Systems, Inc. All rights reserved |  Sitemap