Easily put the Smart into your Home
UPB Switches:
The most reliable, customizable, and easy-to-install Power Line Automation switches ever made. ZERO New Wires Required!
|
Only $79.95
|
View All Switches ยป
|
|
|
 |
Shop > ACT > RB104
|
ACT Box Mount Receiver, Controllable Form C Relay
|
|
|
|
Enlarge Image
|
X10/A10, Standard and Extended Addressing (120/208 VAC, 30A)
Applications:
- Remote ON/OFF Control of Water Heaters
- Control High Current Loads
- Remote ON/OFF control of HVAC and Unitary Equipment
- Control Parking Lot Lights
- Fail-safe Units "OFF" after power failure
- Fail-safe Units "ON" after power failure
|
|
|
|
|
|
|
|
Description:
The RB104 Unit is an A10 enhanced 120/208 VAC, 50/60 Hz, powerline carrier receiver controlling
a single remote Form C Relay capable of
switching a 30 amp load.
The RB104 will continuously monitor the powerline
for PCC signals, and adjust its gain to filter out line
noise. The RB104 will close or open its relay via
Standard or Extended X10 command.
The RB104 may be remote controlled by addressing
it by its base address or its sub address, or
through groups by the commands ALL LIGHTS
ON, ALL LIGHTS OFF, or ALL UNITS OFF. These
global commands must be configured.
The RB104 will transmit the current relay status
when requested.
The RB104 has an external override input. Two
wires connect to this input. When the wires make
contact, the relay is turned on. When the wires
break contact, the relay is turned off.
The RB104 also has a mode switch to allow the
user to gain manual control of the relay. ON
position turns the relay on, OFF position turns the
relay off and AUTO position allows the software
to control the relay.
The RB104 may also be configured to remember
its relay state upon power up.
The RB104 may be configured with a "time-out"
feature, where the state the relay reverts to ON or
OFF after a specified period of time.
Features:
|
- X10 Standard Code (256 Addresses) and X10 compatible
Extended Addressing capability (4096 addresses)
- Two way powerline communication, reports status upon
"Status Request" for standard or extended addresses
- Easy Push Button Configuring for Standard Unit Address
ON/OFF and:
- Response to "All Lights On" Command
- Response to "All Units Off" Command
- Response to "All Lights Off" Command
- Returning to its last commanded state on power-up
- To select 1-16 hours to "Time Out" Relay
- Factory Configuring for Extended Unit Address ON/OFF and:
Response to "Status Request"
- Advanced A10 circuitry, X10 Signal Compatible
- On/Off/Auto Switch on Cover
- Terminals inside for connection of remote override switch
- One Form C Electrically Held Relay
| Specifications |
| Electrical Requirements |
| Power |
| Supply Voltage | 120/208 VAC, +/-10% |
| Frequency | 50 or 60 Hz |
| Power Consumption | Less than 4.5W |
| Signal |
| Signal Input | X10 Powerline Carrier, sensitive to 50 millivolts |
| Signal Output (Status) | X10 Powerline Carrier, 6V peak to peak @ 5 ohms |
| Fuses | Two (2) 13 x 32mm fast acting fuses rated 0.5A, 600V (control circuit only), user replaceable. |
| Controlled Output |
| Form C Relay | Normally open, normally closed and common connections |
| Resistive | 30A, 277 VAC - N.C. or N.O. contacts |
| Motor | 1 H.P., 120 VAC or 1.5 H.P. 200 -600 VAC - N.C. or N.O. contacts |
| Ballast |
120 VAC, 10A - N.C. contact or 30A - N.O. contact
277 VAC, 10A - N.C. contact or 20A - N.O. contact |
| Tungsten | 2A, 120 VAC - N.C. contact or 10A, 120 VAC - N.O. contact |
| Resistive DC | 30A, 28 VDC, - N.C. or N. O. contacts |
| Mechanical Requirements |
| Power |
| Three (3) 12" 16 AWG Flying Leads | L1 - Black
L2 - Red
N - White |
| One (1) 12" 18 AWG Flying Leads | PCC - Pink |
| Relay |
| Three (3) 12" 10 AWG Flying Leads | N.C. - Blue
N.O. - Gray
COM - Violet |
| Remote Manual Override |
| Connections | Removable Terminal Block with Screw Clamp Connections |
| Tightening Torque | 16 inch-pounds |
| Wire Size | 8 to 18 AWG |
| Wire Strip Length | 5/16" |
| Enclosure |
| Dimensions | 4.8" L x 4.6" W x 1.25" H |
| Weight | Less than 16 ounces |
| Mounting | Hinges/mounts on 4-11/16" x 4-11/16" electrical junction box |
| Environmental Requirements |
| Operating Temperature | 32 to 120 degrees F |
| Storage Temperature | -20 to 150 degrees F |
| Operating Humidity | 5% to 95% non-condensing |
|
|
|
|
|
|
|
|
|
 |
 |
|