X10/A10, Standard and Extended Addressing. Rated 20A, 277 VAC.
Applications:
- Control High Current Loads
- Configure to alternate electrical loads
- Remote ON/OFF control of HVAC and Unitary Equipment
- Control Parking Lot Lights
- Lighting Circuits
|
|
|
|
|
|
|
Description:
The RF124, RF204 and RF304 are A10 enhanced
powerline carrier receivers controlling a single remote
Form C Relay capable of switching a 30 amp
load.
The RF124, RF204 and RF304 will continuously
monitor the powerline for PCC signals, and adjust
their gain to filter out line noise. They will close or
open their relay via Standard or Extended X10
commands.
The RF124, RF204 and RF304 may be remote
controlled by addressing it by its base address or
its sub address, or through groups by the commands
ALL LIGHTS ON, ALL LIGHTS OFF, or ALL
UNITS OFF. These global commands must be
configured.
The RF124 will transmit the current relay status
when requested.
A status LED verifies power to unit, and guides
simple configuring procedure.
Features:
|
- Two way powerline communication. Reports ON/OFFstatus
upon "Status Request" and automatically
- Triac Output controlled by X10 On/Off, Bright/Dim or
Extended Code Preset Dim Signals
- X10 Standard Code (256 Addresses) and X10 compatible
Extended Addressing capability (4096 addresses)
- Two way powerline communication, reports status upon
"Status Request" for standard or extended addresses
- One latching 20 Amp Form A Relay with manual override and
mechanical status indicator - holds last state on power loss.
- Easy Push Button Configuring for Standard Unit Address
ON/OFF and:
- Response to "All Lights On" Command
- Response to "All Units Off" Command
- Response to "All Lights Off" Command
- Enable or disable "Polite Mode"
- Factory Configuring for Extended Unit Address ON/OFF and:
Response to "Status Request"
- Advanced A10 circuitry, X10 Signal Compatible
- Flying leads for field connection
| Specifications |
| Electrical Requirements |
| Power |
| Supply Voltage +/-10% | RF124: 120 VAC
RF204: 208/240 VAC
RF304: 277 VAC |
| Frequency | 50 or 60 Hz |
| Power Consumption | Less than 4.5W |
| Fuse (power to relay control circuit only) | One (1) 5mm fuse rated 0.5A for control circuit (factory replaceable only) |
| Signal |
| Signal Input | X10 Powerline Carrier, sensitive to 50 millivolts |
| Signal Output (Status Feedback) | X10 Powerline Carrier, 6V peak to peak @ 5 ohms |
| Controlled Output |
| Form A Latching Relay | With mechanical override and status indicator |
| Maximum switching power | 5000 VA |
| Maximum switching voltage | RF124 - 120 VAC
RF204 - 240 VAC
RF304 - 277 VAC |
| Maximum switch current | 20 Amps |
| Relay Life Cycles at Listed Loads |
| Load Type | 100,000 Operations | 30,000 Operations |
| Incandescent Lamp | 1250W | 2500W |
| Fluorescent Lamp | 1200W | 2500W |
| Low Voltage Halogen w/ transformer | 500VA | 500VA |
| HID Lamp | 1000W | 2000W |
|
|
| Mechanical Requirements |
| Dimensions | 2.7" L x 1.75" W x 1.6" H |
| Weight | Less than 16 ounces |
| Mounting | Double sided foam tape for attachment in electrical junction box |
| Connections | Flying Leads. HOT-12 AWG, LOAD-12 AWG, Neutral-16 AWG |
| Environmental Requirements |
| Operating Temperature | 32 to 120 degrees F |