x10
  Aube Relay Controls a gas, oil or electric furnace and the fan when adding a heat pump to an existing heating system
 
Aube Relay Controls a gas, oil or electric furnace and the fan when adding a heat pump to an existing heating system Controls a gas, oil or electric furnace and the fan when adding a heat pump to an existing heating system

Features
  • Compatible with the TH144 Series thermostat
  • Clearly labeled wires and connections enable simple installation and servicing
  • Compatible with most other heat pump thermostats
  • Compact size permits installation on or inside an electrical box
  • Integrated design eliminates need for two-relay setup
  • Low voltage dry contact output activates auxiliary heating system
  • Line voltage contact output controls fan
Item # RC845
$30.95  
Low Prices Guaranteed!
Free Technical Support
Shipping Rates
Availability:
Special Order
Display All:
Aube
Overview Manual x10
Specifications
Product Features:
Auxillary Heat Contacts Resistive load: 30 V / 5 A
Input signal (W): 24 V / 22 mA
Fan Contacts Volts: 120/240
Resistive load: 22 A
Motor: 0.8 HP @ 120 V / 1.5 HP @ 240 V
FLA: 16 @ 120 V/ 12 @ 240 V
LRA: 42
Input signal (G): 24 V / 40 mA
Humidity Limits 0 to 95% non-condensing
Terminal Wire Size 12 AWG
Dimensions (H•W•D) 56 x 82 x 36 mm / 2.2 x 3.2 x 1.4 inches
   
   
   