| Specifications |
| Model |
AX-350MKII |
AX-650MKII |
| Detection Method |
Infrared Photoelectric |
| Range (Outdoor) |
350ft. ( 100m ) |
650ft. ( 200m ) |
| Maximum Arrival Distance |
3500ft. ( 1000m ) |
6500ft. ( 2000m ) |
| Beam Characteristics |
Pulsed Infrared |
| Selectable Beam Frequency |
4 Channel ( Automatic Synchronization
) |
| Interruption Period |
50 ~ 500msec (Selectable) |
| Power Input |
10.5 ~ 30VDC |
Current Draw
(Transmitter+Receiver) |
Normal operation
75mA max |
| During optical alignment 145mA
max |
| Alarm Period |
2 sec (±1) nominal |
| Alarm Output |
Form C Relay ( 28V DC 0.2A max
) |
| Tamper Switch |
N.C. opens when cover is removed |
| Operating Temperature |
-30° F 131° F ( -35°C
+55°C ) |
| Environment Humidity |
95% Max. |
| Alignment Angle |
± 10° Vertical, ± 90° Horizontal |
| Mounting |
Wall or Pole |
| Environmental Disqualification Circuit |
Form C relay operates when beam
energy has been gradually reduced to abnormal level. |
| Alarm Memory |
LED indicates memory status.
Selectable Negative & Positive |
| Weight |
95.2 oz(2700g) (Both Transmitter
and Receiver) |
*Specifications and design are
subject to change without prior notice.
NOTE: This unit is designed to detect movement and activate
an alarm control panel. Being only part of a complete alarm
system, we cannot assume responsibility for theft or damages,
should it occur. |