  X10 PRO In-Line Dimmer Fixture Module
 
X10 PRO In-Line Dimmer Fixture Module
Enlarge Image
The XPDF Incandescent Dimmer Fixture is designed to control Incandescent loads of up to 300W. The XPDF is small enough to fit inside recessed lighting cans and single gang boxes of new or existing loads, allowing hard wired control from inside the fixture.

Note: Do not use to control Receptacles, Fluorescent Lighting, Motors or Transformers. Only for use in fixtures where 60 Degree C. wiring is permitted. Maximum ambient operating temperature: 140 Degrees F. (60 Degrees C.) The XPDF responds to ON/OFF, BRIGHTEN/DIM, and ALL LIGHTS ON/ALL UNITS OFF.
Item # XPDF
$21.95  
Shipping Rates
Free Technical Support
Low Prices Guaranteed!
Availability:
Item is Available
Display All:
X-10 Pro
Overview More Info x10
Installing the Incandescent Dimmer Fixture:
  • Shut off power at the circuit breaker.
  • Identify the leads from the fixture, (Line and neutral).
  • Interrupt the 120VAC line, that had supplied power to the fixture, then connect the Blue (Switch Leg) from the XPDF to the Fixture as Line.
  • Connect the Black (120VAC, Line) lead from the XPDF to 120VAC.
  • Connect the White (Neutral) lead to Neutral.
  • Clean mounting surface, remove protective covering from adhesive tape on back and press firmly in place.
  • Check that all connections are tight and no bare conductors are exposed.
Setting up the Incandescent Dimmer fixture:
  • Set the House Code dial (RED) to the same letter set on the controller or Security Console. The House Code for monitored security consoles is downloaded by the security installation firm. The default House Code is 'A', when using the PRO2000.
  • For normal lighting control, set the Unit Code dial (BLACK) to an unused code which can be controlled from the controller or an RF remote such as the Security Remote, PSR01 (switches 1- 4 control Unit Codes 1-4).
  • To use as the security light, set the Unit Code to the match the Unit Code of the security console. The Unit Code for monitored security consoles is downloaded by the security installation firm. The default Unit Code is '13', when using the PRO2000.
Note: The security light is the light which is flashed on/off during an alarm and is controlled by the security LIGHT ON and LIGHT OFF buttons on the PRO2000 console, keychain and security remotes)