X10 PRO Single Receptacle Module
|
|
|
|
Enlarge Image
|
Can be used for 20A 220V motors or pumps. Does not respond to "All Lights On". No feed through connectors.
Receptacle Modules offer remote control of various appliances and can be used in place of plug-in Appliance Modules for a more professional look.
|
|
|
|
|
|
Installation Instructions for XPR2
X10 PRO 250VAC Single Receptacle
BEFORE YOU BEGIN...
READ ALL INSTRUCTIONS
Make sure your installation will conform to all applicable codes and requirements.
TEST FOR SIGNAL STRENGTH AND NOISE...
Using the Signal Strength Indicator and Signal Test Transmitter. It is necessary to test the installation in the actual operating environment. The amount and types of line loads may reduce the strength of the transmitted signal and/or electrical noise may cause interference with the transmitted signal. Proper installation may require additional couplers, filters or repeaters. Special coupling devices are required to allow signal to be distributed to all phases and zero-crossings in multi-phase and multi-transformer distributions.
There are no field repairable assemblies on this unit. It is covered by a two year limited warranty. If service is needed, the unit must be returned where purchased.
INSTALLATION
CAUTION! Make all connections with the POWER OFF to avoid injury to the installer or damage to the device.
- Strip 3/4" of insulation from the ends of the conductors and make connections as shown in the Wring Diagram.
NOTE! Securely tape and cap the Blue lead if it is not used,
- Check connections to be sure they are tight and no bare conductors are exposed.
- Make sure the load or installation does not exceed the device rating.
CAUTION! The TOTAL loads connected to this receptacle cannot exceed 20amps @250VAC.
- Install into a standard single or multi-gang electrical wall box. Use a deep box to avoid interference with box fittings and allow room for wiring connections.
Mount the device in the wallbox and install the cover plate/trim ring (Decora TM or compatible style cover plates for ganged receptacles are available through electrical supply vendors).
CHECKOUT
|
- Restore the power.
- Set the address:
Up to 256 addresses can be selected from the module, The address consists of a Letter Code (A through R) and a Number Code (1 through 16) for Unit address. Set the address code dials as shown in the Wring Diagram.
- Test Remote Operation:
Using a controller, transmit "OFF' and "ON" and "ALL UNITS OFF' commands to ensure the device turns the controlled load on and off in response to remote control. (Will not respond to"ALL LIGHTS ON").
- Test for Signal Strength and Noise once again using the Signal Strength Indicator and Signal Test Transmitter.
|
|
|
|
|
|
|
 |
 |
|