OWN A WEBSITE? EARN CA$H!

Become our Partner and Start Earning Money Today!
Join SmartHomeUSA's Official Affiliate Program
Simply register your website's domain with us and earn a percentage of every sale you send our way!
|
|
|
 |
Shop > X-10 Pro > XPS2
|
|
|
Enlarge Image
|
Does not respond to "All Lights On". Ivory Only. Neutral required for master switch.
|
|
|
|
|
|
Installation Instructions for XPS2
X10 PRO 250 VAC Double Pole Feed-Thru Switch Without "All Lights On" Feature
Before you Begin
- Read all Instructions
- Make sure your installation will conform to all applicable codes and requirements.
- Test for Signal Strength and Noise:
Using the XPTR Signal Strength Indicator and XPTT Signal Test Transmitter. It is necessary to test the installation in the actual operating environment. The amount and types of line loads may reduce the strength of the transmitted signal and/or electrical noise may cause interference with the transmitted signal. Proper installation may require additional couplers, filters or repeaters. Special coupling devices are required to allow signal to be distributed to all phases and zero-crossings in multi-phase and multi-transformer distributions.
There are no field repairable assemblies on this unit. It is covered by a two year limited warranty. If service is needed, the unit must be returned where purchased.
CAUTION!
Make all connections with the POWER OFF to avoid injury to the installer or damage to the device.
- Strip 3/4" of insulation from the ends of the wires to make connections to the XPSS- l/XPSS-Was shown in the Wring Diagram.
- Check connections to be sure they are tight and no bare conductors are exposed.
- Make sure the load or installation does not exceed the device rating.
- Install into a standard single or rnulti-gang electrical wall box. Use a deep box to avoid interference with box fittings and allow room for wiring connections.
Mount the device in the wallbox and install the cover plate. If you are using a multi-gang installation, you will need the appropriate trim plate (DecoraTM style cover plates for multi-ganged switches are available through electrical supply vendors).
CHECKOUT
|
- Restore the power.
- Test Local Operation: Depress the switch plate on the XPS3 or XPDI3 series 3-way Master switch several times to ensure the module turns the controlled load on and off in response to manual control.
- Test Slave Operation: Depress the switch plate at each XPSS-l/XPSS-Win the 3-way (4-way,etc.) circuit several times to ensure the module turns the controlled load on and off in response to manual control.
- Test Remote Operation: Using a controller, transmit "OFF', "ON", "ALL UNITS OFF' and "ALL LIGHTS ON' commands to ensure the device turns the controlled load on and off in response to remote control.
- Test for Signal Strength and Noise once again using the Signal Strength lndicator and Signal Test Transmitter.
|
|
|
|
|
|
|
 |
 |
|